Additional Details
Overview
totally configurable safety module monitors numerous safety devices such as e-stop buttons, interlocking switches, safety light screens, two-hand controls and rope pull switches.
22 input terminals can monitor both contact-based or pnp solid-state outputs from banner devices or any other manufacturers
each input can be a non-safety input, or configured for control reliability or category 2, 3 or 4 safety circuit performance per iso 13849-1
3 pairs of solid-state safety outputs rated at 0. 75a each (24v dc) with selectable one- or two-channel external device monitoring and on-delay or off-dalay
10 configurable auxiliary status outputs track inputs, outputs, lockout, i/o status and other functions
easy configuration with built-in front panel lcd display or pc interface
live display and a fault log provide real-time system and fault history identification
controller is designed to meet stringent standards including safety integrity level (sil) 3 per iec 62061 and iec 61508, and category 4 performance level (pl e) per iso 13849-1