Additional Details
Overview module connects to two sensors with pnp outputs, monitoring rotation (rpm) or linear movement. Provides over-speed, under-speed and zero-speed detection. feedback input monitors external machine control elements 24v ac/dc operation two redundant, forced guided output contacts rated at 4a, plus one auxiliary n. C. Output contact stop category 0, per iso 13850 (en 418), iec 60204-1, and ansi nfpa 79; category 3, sil claimed level (sil cl) 3 to en 62061, category 3 / performance level (pl) e to din en iso 13849-1 din-rail mountable 45 mm wide housing with removable terminal blocks energizes output relays (closes n. O. Contacts), when speed drops below set value, for "standstill" (under-speed) monitoring de-energizes output relays (opens n. O. Contacts), when speed rises above set value, for over-speed monitoring