Reactivation or regeneration of desiccant is then necessary to drive-off the adsorbed moisture and to re-store its original absorptive capacity. This is accomplished via purging the adsorbent by dry air or gas at atmospheric pressure and temperature in reverse direction.
Actual Operation: Heatless Drying Unit has two towers filled with the desiccant for continuous drying operation. At a time, one tower is used for drying while the other tower is reactivated simultaneously. After a fixed time of interval, the drying towers get changeover automatically by operation of sequence timer and interconnected valves. Referring to the flow diagram, assume that the left tower is under drying and the right tower is under Reactivation. Wet air or gas enters the tower from bottom side, passes up through the desiccant and comes out from the top. A small bleed flow is split from the exit of left tower and enters the right tower at atmospheric pressure. This bleed air pick-up the moisture from the desiccant and vented out to the atmosphere. After complete reactivation of desiccant, direction of control valves is reversed to place the left tower on reactivation.
Incepted in the year 2003, it is one of the prominent organizations engaged in manufacturing, supplying and exporting of industrial plants and equipment like industrial filters, industrial heat exchangers, ammonia cracking units, exo gas generators, gas exchangers, gas generators, compressed air / gas drying system, pressure vessels and others.