Additional Details
Model : BP-2239A
Description:
The model DT-2239A is a microprocessor circuit design, high accuracy, digital readout, light duty, Stroboscope/Tachometer that is ideal for inspecting and measuring the speed of moving gears, fans, centrifuges, pumps, motors and other equipment used in general industrial maintenance, production, quality control, laboratories and as well as for schools and colleges for demonstrating strobe action.
Specifications:
Display 0.3" LED 4 digits
Power Supply 110 Vac 10%, 50/60 Hz.
Stroboscopic 100 to 10,000 flashes per or 220 Vac 10%, 50/60 Hz.
Flash Rate minute (FPM). or 230 Vac 10%, 50/60 Hz.
Accuracy 100 to 5,000 FPM/RPM)
Power Less than 30 Watt.± 1 digit.
Consumption over 5000 FPM/RPM
Operating Temp. 0 to 50 (32 to 122 ) ± 0.05%
Operating Less than 80%
R.H. Resolution Less than 10,000 FPM/RPM
Humidity 1 FPM/RPM
Dimension HWD - 21 x 12 x 12 cm Over 10,000 FPM/RPM (8.3x4.8x4.8 inch).10FPM/RPM
Weight 1Kg/2.2 LB
Sampling Time 1 second
Housing compact and impact plastic range select automation.
Injection case with Plastic Circuit
This stroboscope/tachometer mirror type reflector, employs an custom one-chip calibration crystal time base and of microcomputer LSI circuit microprocessor circuit, don't& crystal control time base necessary take any external which results in extraordinary calibration process accuracy over a wide, dynamic accessories operation manual 1 PC.range.
Included Flash Tube Specifications:
Flash Tube Xenon Lamp:
It is required to change the flash duration approximately 60 to 1,000 replacement flash tube when the microseconds instrument start to flash flash color Xenon white 6,500 K degree irregularly at speeds of 3600 flash energy 4 watts-seconds (joules). RPM/FPM or more. Beam angle 80 operating duty for prolong life and safe operation
Please Adhere To The Following Duty Cycle:
Cycle Below 1,000 RPM - 30 Minutes.
Above 3,600 RPM - 5 Minutes
Always allow a 10 minute cooling off period between cycles
Operations Procedures:
Preparation:
Plug unit into a properly grounded 110V AC, 220V AC or 230V AC outlet
Turn the power switch to "on" position.(c) Determine the range switch to "Low" or "High" position
Checking Speed: When checking speed, care must be taken to insure that the strobe is flashing inunison (one to one) with the object being monitored. A Stroboscope will also stop motion at 2:1, 3:1, 4:1 et., this is normally referred to as harmonies. To be sure of unison, turn the dial until two images appear - this will double the actual speed. Then lower the flashing rate until a single and stationary image appears -this is the actual true speed.
Checking Motion For Motion Analysis:
Simply locate the actual speed as mentioned above and then turn the dial slowly up or down. This will give a slow motion effect allowing complete inspection
Remark : When order the stroboscope, should inform the power supply types which is is AC 110 V, 220 V or 230 V.*
Appearance and specifications listed in this brochure are subject to change without notice.