Amplifier Unit | ||
ACOUSTIC AMPLIFIER
|
MAGNETIC AMLIFIER
|
|
Signal Input
|
Balanced from acoustic pick up.
|
From coil housed within amplifier.
|
Supply Voltage & Battery Life
|
12 VDC (1.5X8 Pencil cells)
|
> 15 Hrs on intermittent use
|
Supply Current (No Signal)
|
3mA
|
3mA
|
Input Resistance (Input to ground)
|
2kohms | 2kohms |
Control
|
Gain control
|
Sensitivity Control
|
Indication
|
Acoustic signal via headphone.
|
Proportional signal level meter.
|
Gain
|
> 65 db
|
> 76db
|
Frequency
|
270 Hz to 1.5 KHz
|
100 Hz to 10 KHz
|
Coincidence display range
|
0 to 99 mS
|
|
Transducer (Acoustic Pickup)
|
||
Damping
|
70%
|
|
Sensitivity
|
0.02V/mm/sec
|
|
Connecting Cable
|
1.5m
|
|
Headphones
|
Dynamic headphones with a padded earpieces and adjustable head band.
|
|
General
|
32 ohms
|
|
Impedance
|
||
MECHANICAL
|
||
AMPLIFIER UNIT
|
TRANSDUCER UNIT
|
|
Size
|
25.5x13.5x12.5cm
|
6.6x10cm
|
Weight
|
1.400 Kg with Batteries
|
1.2 Kg approx with rod
|
Size/Weight with casing (Complete Set)
|
50cm(L)X40cm(W)X16cm(H) and 5.125 Kg. |
For pin-pointing of cable faults DIGIPOINT is used with the headphone and Surge Generator (T-1004,T-1005,T-1020,T-1032). The Surge Generators are devices used for precise location of faults in power cables with the acoustic method. This method provides for the charging of a capacitor with the pulse voltage which is then downloaded to the cable fault through a spark gap.
With the use of the detector, as well as the acoustic is also measured the time between the arrival of the magnetic wave and the sound. Therefore approaching the fault point to the time difference becomes progressively smaller until reaching a minimum value above the fault.
The main parameters detected by the detector are:
Relative distance from the magnetic and acoustic fault in ms. The lower the value the closer the fault.
· Intensity of the magnetic signal present at the location to confirm the presence of the cable and its location.
· Confirmation of the acoustic signal.
· Confirmation of the magnetic signal.
Techno established in the year 1987 is leading organization engaged in manufacturing and exporting of power cable fault locating instruments. Cable fault locator is used for tracing the route and finding faults in underground cables in several power generation, transmission and regulation applications.
More details:View company website
Its Free
Verify Now