Welcome to Pepagora.com, Join FreeSign In
Transmission Line Analyzer
Overhead Line Fault Locator
Corona Detection System
Insulation Analyzer
Earth Resistance Tester
Earth Fault Locator
Earth Fault Monitoring System
Leak Rate Detector
Earth Ground Resistance
Its Free
We are offering high quality Transmission Line Fault Analyzer. With its unique features and capabilities these are ideal choice for the virtual patrolling and identifying all type of fault and inhomogeneities of entire transmission line.
We are offering high quality Transmission Line Fault Analyzer. With its unique features and capabilities these are ideal choice for the virtual patrolling and identifying all type of fault and inhomogeneities of entire transmission line.MAX-3 Digi Scan is an auto-calibrated portable system comprising of 5 main units: Fault Locator unit; Adapter unit; Signature Analyzer unit, Simulator unit, Computing System loaded with Taurus Data Management Software (TADMA). The system being a portable kit can be used on any de-energised line from 66 kv to 1250 kv.Distinct Advantages: MAX-3 is a transmission line fault analyzer which is useful in accurately identifying; all types of open & short circuit fault and inhomogeneities on the transmission line through line signature analysis. Fault Location: Direct Digital display of distance to fault with the accuracy of ±100m. Useful for all type of Open circuit faults; Phase to Phase faults; Phase to Earth fault and Insulator De-capping.Zoom Blanking: Unique capability to easily detect faults on spur lines and other applications with extended range blanking facilityLine Signature Analysis Study (LSA): Reveals all the inhomogeneities prevalent along the transmission line. Serial comparison of this data enables the user to infer deteriorating points along the line which could be the cause of power loss, sporadic tripping and eventual line breakdown.LSA is useful in: Identifying Faults; Safe Recharging of Line; Line Diagnostic Study Monitoring; Moving from Preventive to Predictive Maintenance; New Line Pre-commissioning Certification.Portability & Flexibility: Portable off-line system with inbuilt rechargeable batteries can be used as and when required or at periodic intervals on any de-energised line emanating from a sub-station.Higher Return on Investment: With its remarkable capability of higher resolution, MAX — 3 can analyze faults faster, with a higher accuracy and more precisely than any other fault detecting/analyzer systems.Features: