Welcome to Pepagora.com, Join FreeSign In

Bonded Fibre Glasswool

Fiber glasswool insulation rolls and slabs with or without facing, ceiling tiles, MFMB, underdeck board for thermal and acoustic insulation.

  • FOB Price
    NA
  • Min Order Quantity
    NA
  • Payment Terms
    NA
  • Share:
Request for Quote

Other Details

Fiber glasswool insulation rolls and slabs with or without facing, ceiling tiles, MFMB, underdeck board for thermal and acoustic insulation. Types of facings: FSK, WMP-10, WMP-30, WMP-VR, ASJ 30, BGT and Glass Cloth.

Product Range

Density 12 Kg/Cubic m to 100 Kg/Cubic m and thickness 12mm to 100mm.

Temperature Range

Fibre Glass Insulation is suitable for applications ranging from minus 195 degree Celsius to plus 230 degree Celsius. For special applications upto 450 degree Celsius, high temperature binder is used. Aluminum foil facing is suitable upto 120 degree Celsius.

Chemical Stability

Fibre Glass Insulation is chemically inert. Application does not cause or accelerate corrosion.

Fibre Glass Insulation is rot proof and odourless.

Fire Safety

Fibre Glass Insulation is non-combustible in accordance with BS 476 Part 4, 1970.

Incombustible.

Low fire propagation(index 13.58).

Extremely low spread of flame(class 1 BS 476 Part 7).

Non emission of dense smoke and toxic gases(low toxicity index 0.86).

Non depletion of oxygen (high oxygen index 70%).

Biological

Fibre Glass Insulation is inorganic. Does not encourage growth of fungi and vermin.

Dimensional

Fibre Glass Insulation is stable under varying conditions of temperature and humidity when applied correctly. Excellent tear strength and not prone to sagging or settling. Rigid slabs have inherently high compression resistance.

Vibration and Jolting Resistance

Conforms to BS 2972.

Moisture Content

Less than 2% in accordance with BS 2972.

Water Absorption

Less than 2% in accordance with BS 2972.

Shot Content

Nil in accordance with BS 2972.

Odourless

Conforms to BS 2972.

No Mould Growth

Conforms to BS 2972.

Recovery after Compression

More than 95% in accordance with BS 3958 Part 5.

Images

Email to this Supplier