Welcome to Pepagora.com, Join FreeSign In

NITROGEN GAS PLANT

Being the most dedicated certified organization guided by experienced and knowledgeable professionals, we offer quality premium quality Nitrogen Gas Plant.Our service meets the customer's request.

  • FOB Price
    NA
  • Min Order Quantity
    NA
  • Payment Terms
    NA
  • Share:
Request for Quote

Product Details

  • Type

    Nitrogen Gas Plant
  • Construction

    Strong And Sturdy
  • Maintenance Cost

    Low
  • Standard Or Non-Standard

    Standard
  • Price

    Negotiable
  • Shape

    Elongated Cylinder
  • Gas

    Nitrogen
  • Pressure

    High Pressure
  • Use

    Industrial Gas

Other Details

Product Data:

In reference to 100 M3 / Hr capacity plant. The nitrogen gas plant can produce essentially oxygen and the nitrogen gas generator. However, the nitrogen production plant can be controlled with nitrogen to produce these products in various standard modes, as indicated below, based on standard operating conditions:

Production cycle -I:

Oxygen-gaseous-dry-99.5% and above purity-100 M3 / Hr. 

Production cycle -II:

Oxygen-gaseous-dry-99.5% and above purity-93 M3 / Hr. Nitrogen-gaseous-99.6 to 99.8% purity-125 M3 / Hr. Filling of this nitrogen in the cylinders, at an additional cost).

Nitrogen gas plants in Mumbai:

Price inquiry:

Production cycle -III:

Oxygen-gaseous-dry-99.5% and above purity-93 M3 / Hr. Nitrogenous liquid 15 to 18 Ltrs. Purity per hour 99.9%

Production cycle -IV:

Oxygen-gaseous-dry-99.5% and above purity -70 M3 / Hr Dry gaseous nitrogen - Less than 10 PPM purity = M3 / Hr Dry gaseous nitrogen - Less than 10 PPM purity = M3 / Hr

 

Technical Specifications

 

Technical Data

Specifications

130 M3/Hr.

170 M3/Hr.

200 M3 / Hr.

Air Compressor Capacity

740 M3/Hr.

950 M3/Hr.

1150 M3/Hr.

Starting Pressure

40 Kg/cm2

40 Kg/cm2

40 Kg/cm2

Operating Pressure

30-35 kg/cm2

30-35 kg/cm2

30-35 kg/cm2

Starting time till production

7 Hrs.

7 Hrs.

7 Hrs.

Defrosting time

4/6 Hrs.

4/6 Hrs.

4/6 Hrs.

Defrosting cycle at normal condition

12 months

12 months

12 months

Power supply required

420V 220V 3Phase 50 Hz

420V 220V 3Phase 50 Hz

420V 220V 3Phase 50 Hz

Rate through put of liquid Oxygen Pump

130 M3/Hr.

170 M3/Hr.

200 M3/Hr.

Delivery Pressure of pump

165 kg/cm2

165 kg/cm2

165 kg/cm2

Cylinder filling manifold

2 X 12

2 X 20

2 X 20

Cooling water requirement

40 M3/Hr. (Re-circulated)

50 M3/Hr. (Re-circulated)

70 M3/Hr. (Re-circulated)

Make-up water requirement

Approx. 0.5 M3/Hr.

Approx. 0.5 M3/Hr.

Approx. 1 M3/Hr.

Max. Individual item weight

8.5 Tons

10 Tons

11 Tons

Gross Weight

20 Tons (approx.)

32 Tons (approx.)

40 Tons (approx.)

Insulation

Perlite.

Perlite.

Perlite.

Assembly Height

8.0 meters

9.2 meters

9.2 meters

Area required

200 sq.mtrs.

250 sq.mtrs.

350 sq.mtrs.

Material of construction

Copper, Brass, Steel etc

Copper, Brass, Steel etc

Copper, Brass, Steel etc

Power consumption

1.2 units/M3 of Oxygen

1.0 units/M3 of Oxygen

1.0 units/M3 of Oxygen

Images

Email to this Supplier