Welcome to Pepagora.com, Join FreeSign In

High Pressure Refrigerated Air Dryer

  • FOB Price
    NA
  • Min Order Quantity
    1-Pieces
  • Payment Terms
    NA
  • Share:
Request for Quote

Product Details

  • Configuration
    Portable
  • Lubrication Style
    Lubricated
  • Mute
    Yes
  • Power Source
    Diesel
  • Type
    Reciprocating

Technical Specifications

Base Model

Air Flow

 

Ref. Power

Electrical Connection*

 

Inlet / Outlet

Dimensions 
(mm)

 

 

Weight

CFM

m³/h

kW*

220V / 
1Ø/50Hz

415V / 
3Ø/50Hz

BSP

A

B

C

kg.

2KD0027

20

34

0.21

http://gemindia.com/images/tick.gif

-

½"

360

475

550

45

2KD0047

40

68

0.36

http://gemindia.com/images/tick.gif

-

½"

360

475

550

47

2KD0067

60

100

0.36

http://gemindia.com/images/tick.gif

-

½"

360

475

550

47

2KD0087

80

136

0.48

http://gemindia.com/images/tick.gif

-

1"

500

600

730

78

2KD0107

100

170

0.60

http://gemindia.com/images/tick.gif

-

1"

500

600

730

90

2KD0157

150

255

0.68

http://gemindia.com/images/tick.gif

-

1"

500

600

730

90

2KD0207

200

340

1.0

http://gemindia.com/images/tick.gif

-

1½"

700

700

830

120

2KD0257

250

425

1.4

http://gemindia.com/images/tick.gif

-

1½"

700

700

830

135

2KD0307

300

510

1.4

http://gemindia.com/images/tick.gif

-

1½"

700

700

830

135

2KD0407

400

680

1.8

http://gemindia.com/images/tick.gif

-

2"

900

900

1230

170

2KD0507

500

850

2.2

-

http://gemindia.com/images/tick.gif

2" NB flg

900

900

1230

180

2KD0757

750

1275

3.3

-

http://gemindia.com/images/tick.gif

2" NB flg

750

1000

1400

250

2KD1007

1000

1700

4.2

-

http://gemindia.com/images/tick.gif

2" NB flg

900

1200

1475

350

Sizing Conversion Factors:

Inlet Temperature (C1)    

Temperature °C

30

35

40

45

50

55

60

Correction Factor

1.2

1.15

1.05

1.0

0.85

0.7

0.6

Ambient Temperature (C2)        

Temparature

25

30

35

40

45

50

Correction factor

1.2

1.15

1.1

1.05

1.0

0.9

Inlet Pressure (C3) 

Inlet Pressure

bar (g)

4

5

6

7

8

9

10.5

11

12.5

13

14

15

16

psi (g)

58

73

87

100

116

131

150

160

180

189

200

218

232

Correction Factor

.

0.75

0.85

0.95

1.00

1.06

1.04

1.07

1.18

1.09

1.22

1.12

1.25

1.14

Dew Point (C4) 

Dewpoint in C

3

7

10

Correction Factor

1.0

1.15

1.3

Dryer Normal Capacity =               Actual Capacity × C4C1 × C2 × C3

Operating conditions

Ideal

Maximum

Inlet temperature

45°C

60°C

Ambient Temperature

35°C

50°C

Working pressure

40 bar

42 bar

Pressure Dew point

3°C

NIL

 

 

Images

Email to this Supplier